5 min read

SBA 492: Breaking Down ASHRAE 62.1

By Smart Buildings Academy on Apr 24, 2025 7:00:00 AM

Topics: Podcasts

Episode Description:

Good air is about performance, health, and operational excellence. This episode of the Smart Buildings Academy Podcast explores the critical role that ASHRAE 62.1 plays in creating environments where people can thrive. Controls technicians, facilities managers, commissioning agents, and mechanical designers will benefit from understanding this essential ventilation standard.

Building professionals often recognize the importance of indoor air quality but may struggle to achieve it consistently. This episode highlights why simply moving air is not enough and what it takes to deliver clean, safe, and effective ventilation tailored to every space. The discussion provides a deeper appreciation for the nuances of air quality standards and their impact throughout the building lifecycle.

Key Topics Explored:

  • The meaning of ventilation and why airflow alone is insufficient
  • How ASHRAE 62.1 sets minimum requirements for indoor air quality in commercial buildings
  • The differences between the three approved ventilation methods and when to apply each
  • The importance of commissioning and maintenance in sustaining healthy air environments
  • How improper system installation and neglect can compromise even well-designed projects

ASHRAE 62.1 ensures that buildings protect the health of occupants. Listen to Episode 492 to gain critical insights that can strengthen your projects and professional expertise

Click here to download or listen to this episode now.

Podcast Video


itunes-button-300x109
Subscribe via iTunes

stitcher
Subscribe via Stitcher

How ASHRAE 62.1 Protects Building Health and Performance

Indoor air quality is one of the most influential factors in the health, productivity, and satisfaction of building occupants. Yet it is often overlooked in both design and operations. ASHRAE 62.1 provides a clear framework to address this challenge. In Smart Buildings Academy Podcast #492, the standard is broken down into practical insights for building automation professionals.

Ventilation Beyond Airflow

Ventilation is often misunderstood as simply moving air through a space. In reality, it involves managing contaminants, humidity, and temperature to maintain a safe and comfortable environment. Poor ventilation can cause a noticeable decline in cognitive performance, energy levels, and overall occupant health. Understanding this deeper purpose of ventilation is essential for anyone responsible for building operations or system design.

Outdoor Air: A Critical First Step

ASHRAE 62.1 emphasizes that outdoor air must be assessed before it is brought into a building. Pollutants such as particulate matter, ozone, carbon monoxide, and regional contaminants must be measured against national thresholds. If these pollutants are found to be above acceptable limits, treatment systems such as filtration or UV purification must be integrated before the air reaches occupied spaces. Not all outdoor air can be considered fresh without intervention.

Three Methods for Ventilation Design

The standard outlines three approved procedures for determining ventilation rates:

  • Ventilation Rate Procedure (VRP): Based on space type, occupant load, and floor area

  • Indoor Air Quality Procedure (IAQP): Based on achieving measurable contaminant targets

  • Natural Ventilation Procedure: Based on proven airflow through windows, louvers, or other passive methods

Each method addresses different project needs, with VRP being the most common default. IAQP allows flexibility but carries risks if not carefully monitored. Natural ventilation suits specific climates and building types but must meet strict performance criteria.

Why Commissioning and Maintenance Matter

Meeting ASHRAE 62.1 is not achieved at project handoff. Systems must be properly commissioned to verify airflow, damper positioning, sensor calibration, and control logic. Without functional verification, even the best-designed system can fail to deliver healthy indoor air.

Maintenance must also be continuous and documented. Filters must be replaced on schedule. Damper motors must be tested. Building automation systems must be configured to monitor and alarm on deviations. Performance tracking is essential to protect the investment made during design and commissioning.

ASHRAE 62.1 as a Lifecycle Standard

ASHRAE 62.1 is not a checklist for design. It is a commitment to long-term building performance and occupant well-being. By addressing intake air quality, tailoring ventilation to space use, verifying installation quality, and maintaining systems rigorously, professionals can ensure their buildings promote health and productivity for years to come.

Building automation professionals, facility managers, and engineers must see ASHRAE 62.1 as a foundation for operational excellence, not just compliance. Mastery of this standard will separate those who design for code from those who design for true building performance.

For a deeper discussion and insights from the field, listen to this episode on the Smart Buildings Academy podcast